| Safety standard |
Meets the requirements for double insulation to IEC 1010-2-032,
IEC 1010-1(1995), EN 61010-1(1995) installation CategoryII600V phase to earth,
CategoryIII300V phase to earth. |
| E.M.C. standard |
The instrument meets EN 50081-1 and EN 50082-1 (1992). |
| Measuring method |
Successive approximation mode |
| Display |
4 digit LCD max. reading of 9999 |
| Measuring range |
AC Current 1000A
DC Current 1000A
AC Voltage 500V
DC Voltage 500V
Resistance 600 W |
| Accuracy |
23oC¡À5oC 80%RH or less
| AC Current (AC) |
0~600A
600.1~999.9A |
¡À1.5%rdg¡À8dgt
¡À3.0%rdg¡À8dgt |
| DC Current (DC) |
0~600A
600.1~999.9A |
¡À1.5%rdg¡À3dgt
¡À3.0%rdg¡À3dgt |
| AC Voltage (AC) |
0~500.0V |
¡À1.0%rdg¡À8dgt |
| DC Voltage (DC) |
0~500.0V |
¡À1.0%rdg¡À3dgt |
| Resistance ( W) |
0~600.0 W |
¡À1.0%rdg¡À3dgt |
|
| Jaw opening capability |
Ø30mm |
| Over range indication |
" OL " mark on LCD. |
| Low battery indication |
"B" mark on LCD |
| Data hold indication |
"DH" mark on LCD |
| Max. display function |
"Max" mark on display, indicating max. value during measurement. |
| Min. display function |
"Min" mark on display, indicating min. value during measurement. |
| 0 adjustment |
for DC current range, can make display to 0 by ADJ switch. |
| Sampling time |
2 times/sec |
| Circuit voltage |
less than AC/DC 500V. |
| Withstanding voltage |
AC 3700V 1 minute max. (Between the core of CT and outer case) |
| Operating temperature |
0oC to~40oC<80%RH ( without condensing ) |
| Storage temperature |
-10oC to ~ 60oC<70%RH ( without condensing ) |
| Power supply |
SR-44(1.55V)x2 or LR-44x2 |
| Battery life |
6h |
| Power Consumption |
Approx.12mW |
| Size |
44.5(W)x177(H)x24(D)mm |
| Weight |
Approx. 95g |
| Accessories |
Soft casex1
Instruction manualx1
Batteries, LR-44(1.55V)x2
Test Leadx1
|